Digilent Analog Discovery 3 vs Hantek 6022BE
Head-to-head spec comparison to help you pick the right scope for your bench.
Spec-by-Spec Comparison
| Spec | Digilent Analog Discovery 3 | Hantek 6022BE |
|---|---|---|
| Bandwidth | 50 MHz | 20 MHz |
| Sample Rate | 0.125 GSa/s | 0.048 GSa/s |
| Channels | 2 | 2 |
| Memory Depth | 32 Kpts | Capture depends on software |
| Display Size | N/A | N/A |
| Weight | 0.15 kg | 0.2 kg |
| Price | $374.95 | $69.99 |
| Rating | 7.5/10 | 4.5/10 |
| Protocol Decoder | Yes | No |
| Function Gen | Yes | No |
| WiFi | No | No |
| Battery | No | No |
| Buy on Amazon | Buy on Amazon |
Pros & Cons
Digilent Analog Discovery 3
Pros
- 2 analog channels for simultaneous signal comparison
- 50 MHz nominal bandwidth; 32 Kpts acquisition memory
- Protocol decoding: SPI, I2C, UART, CAN
- Includes a signal-generator function for stimulus and response work
Cons
- Two analog channels limit simultaneous bus and power-rail captures
- 32 Kpts acquisition memory limits long high-rate captures
- Specification-based assessment; no hands-on measurement record is documented
Hantek 6022BE
Pros
- 20 MHz nominal bandwidth with two analog inputs
- Vendor maximum of 48 MS/s; acquisition behavior depends on the selected application
- OpenHantek6022 offers a documented software path; check host and driver requirements
Cons
- Two channels limit simultaneous bus and power-rail captures
- The vendor maximum sample rate is not a sustained software-acquisition guarantee
- Capture depth and trigger features depend on the selected software; check its documentation
Our Verdicts
Digilent Analog Discovery 3
The Digilent Analog Discovery 3 pairs 50 MHz nominal bandwidth with 2 analog channels and 32 Kpts acquisition memory. Its two channels suit input/output or clock/data comparisons, but leave less room for simultaneous power-rail debugging. Protocol decoding can help interpret supported serial buses; check the exact included decoder options. The short acquisition buffer makes capture duration a particular constraint at high sample rates. This recommendation is based on listed specifications, without documented hands-on performance testing.
Hantek 6022BE
For the Hantek 6022BE, choose the application and check its requirements before deciding whether the hardware fits your work. The 20 MHz USB instrument has two analog inputs and a published 48 MS/s vendor maximum, but that rate does not describe every application acquisition mode. Capture depth and triggering depend on the selected software. OpenHantek6022 provides a separate documented software path with host, driver and channel conditions; exact operation on your host remains unverified here.